Main features
  • Double version: model with 4 or 8 independent channels 
  • Wide touch screen color display
  • Programmable test duration and adjustable measuring rate starting from 1 minute
  • Continuously variable voltage difference from 5 to 70 VDC independent for each channel
  • Unlimited data storage on internal 8 GB memory

General description
General description
This test method allows concrete to be evaluated in terms of chloride permeability, this parameter is essen­tial as it influences concrete durability.
The test is performed applying a voltage difference between the ends of a cylindrical specimen, one end is the negative and is immersed in a sodium chloride solution, the other is the positive and is in a sodium hydroxide solution.
 
Testing procedure to ASTM and AASHTO
While keeping 60 VDC difference between the specimen ends, current (Ampere) transmitted through the specimen is accu­rately measured over time calcu­lating the total charge (Coulomb). This value relates to the specimen resistance to chloride ion pene­tration.
In accordance with the Stand­ards indications, starting from the measured total charge, the instrument provides qualitative indications of the chloride ion penetrability level (from High to Negligible).
Two test cells are available de­pending on the specimen dimen­sions:

58-E5220/A1
Complete test cell to ASTM and AASHTO suitable for concrete speci­men dia. 100 mm x 50 mm length. It includes 2 heads and cables, 1 temperature probe, 4 tie rods for cells tightening, 2 gaskets, 1 rigid plastic sleeve for hydraulic seal.

58-E5220/A2
Complete test cell to ASTM and AASHTO suitable for concrete speci­men dia. 100 mm x 200 mm length. It includes 2 heads and cables, 1 temperature probe, 4 tie rods for cells tightening, 2 gaskets, 2 rigid plastic sleeves with 4 internal tie rods for hydraulic seal.

Testing procedure to NT BUILD 492
This test method requires to ad­just the voltage difference start­ing from 30 VDC depending on the transmitted current.
The CI-METER allows continuous voltage adjustment from 5 to 70 VDC. Suggested voltages and test durations are pre-set in the instru­ments to drive the user to the cor­rect test execution.
For this test method, the follow­ing kit is required:

58-E5220/A3
Migration set up kit to NT BUILD 492 for simultaneous testing of up to 3 specimens. It includes:
Transparent plastic tank
3 specimen holders with stainless steel support, plastic spacers, electrodes (+ and -), perforated grids, stainless steel clamps, rubber sleeves, cables
3 temperature probes
 
Test cell for chloride ion penetration meter
Two CI-METER models are available:

58-E5214
for simultaneous test of up to 4 specimens

58-E5218
for simultaneous test of up to 8 specimens

More +

Technical specifications

  • 4 or 8 specimens simultaneous testing (see the models)
  • Each channel is independent
  • Programmable test duration
  • Adjustable sampling rate (starting from 1 minute)
  • Continuously variable voltage difference from 5 to 70 VDC inde­pendent for each channel.
  • Voltage accuracy +/- 0.1V, resolution 0.01 V
  • Continuous current measurement with accuracy +/- 1 mA, resolu­tion 0.1 mA
  • Continuous temperature measure­ment with PT100 probe, accuracy +/- 1°C, resolution 0.1°C
  • Testing data displayed in numerical and graphical mode
  • 7” color display with capacitive touchscreen
  • 8 GB internal memory
  • USB port for data export/storage on external memory (USB pen drive)
  • LAN port for PC connection
  • RS 232 serial port for PC or serial printer connection
  • Friendly interface with pre-set test routines to the main Standards plus custom procedures
Dimensions and weights: 
  • Instrument: (l x w x h) 503 x 330 x 164 mm, 11.5 kg
  • Cell 58-E5220/A1: (l x w x h) 200 x 150 x 150 mm, 3.5 kg
  • Cell 58-E5220/A2: (l x w x h) 350 x 150 x 150 mm, 5 kg
  • Migration set up kit 58-E5220/A3: (l x w x h) 380x270x280 mm, 10 kg
     

Ordering info

58-E5214
4-channel chloride penetration meter. 110-230V, 50-60Hz, 1 ph

58-E5218
8-channel chloride penetration meter. 110-230V, 50-60Hz, 1 ph



 

Accessories


58-E5220/A1 
Complete test cell to ASTM and AASHTO for CI meter for concrete spe­cimen dia. 100 mm x 50 mm height.

58-E5220/A2 
Complete test cell to ASTM and AASHTO for CI meter for concrete spe­cimen dia. 100 mm x 200 mm height.

58-E5220/A3 
Migration set up kit to NT BUILD 492 with 3-place rack suitable for simulta­neous testing of up to 3 specimens

58-E0052/1 
Vacuum system (see ASTM and NT BUILD) for specimen saturation with water. Comprises pump, air drying unit with silica gel, desiccator, glass vessel, stands and clamps. 230V, 50 Hz, 1 ph. Weight 40 kg (approx.)

58-E0052/1Z 
Same as above but 110 V, 60 Hz, 1 ph.

Documents

Contact Us

Controls Group USA, Inc.

2521 Technology Drive, Suite 203
Elgin, Il 60124.
Phone: +1 844 291 4305
Email: info@controls-usa.com
www.controls-usa.com

Having read the information on the data processing:

È necessario effettuare una scelta per proseguire

We will never divulge your data to third parties.

By clicking send button, I confirm that I request the service indicated in point a) of these guidelines; my consent to the processing of data for the purposes of the service, including the processing methods mentioned in these guidelines, including possible processing carried out in EU member states or non-EU countries.