General description
The falling head permeability test is used to determine the permeability of fine grained soils with intermediate and low permeability such as silts and clays with permeability in range of 1x10-5 to 1x10-9. This testing method can be applied to an undisturbed sample. The falling head principle can be applied to an undisturbed sample in a sampling tube and to a sample in an oedometer consolidation cell.

This test method covers laboratory measurement of the hydraulic conductivity of laboratory-compacted materials with a rigid-wall, compaction-mold permeameter and may be used with compacted specimens that have a hydraulic conductivity less than or equal to 1 × 10−5 m/s.

To check all the items see additional information.
More +

Ordering info

38-T0185/KIT1 
 Falling head apparatus.                           
The whole system includes:                         
 - Falling head permeability cell, 100 mm internal dia.                                           
 - Manometer stand with 3 tubes 6,8,14  mm dia. with quick couplings and anchoring system    
   1152x250x34 mm                                                             
 - Soaking reservoir, complete with overflow tube.

38-T0185/KIT2
Falling head apparatus for compacted soil.                           
The whole system includes:                         
 - Compaction mould permeameter, 4" (101.6mm) dia. conforming to ASTM D5856                       
 - Manometer stand with 3 tubes 6, 8, 14 mm dia. with connecting valves and anchoring system 1152x250x34 mm    

For the single componets please see additional infomation 


Accessories

De-airing tank

28-WF4220/A 

De-airing tank, 7 liters capacity
28-WF4221/A
De-airing tank, 23 liters capacity


Vacuum Pump

86-D2001

Portable vacuum pump, free air displacement 75 l/min, ultimate vacuum 0.1 mbar. 230V/50-60Hz/1Ph.

86-D2005
Air drying unit for use with silica gel with the indicator 86-D0819

86-D0819
Silica gel 1 kg

86-D2064
Rubber tube dia 6.5 x 16.5 mm, 2 m long, for vacuum pump.

Additional Information

 

Permeability cell 38-T0185/C1 * Falling head permeability cell, 100 mm internal dia. complete with 75 micron gauze and 2 m of tubing conforming to BS EN ISO 17892-11
38-T0185/C2 ** Compaction mould permeameter, 4" (101,6 mm) dia. conforming to ASTM D5856
38-T0185/C3 Compaction mould permeameter, 6" (152,4 mm) dia. conforming to ASTM D5856
Tank 38-T0185/T * Soaking reservoir, complete with overflow tube
Manometer stand 38-T0183/MS */** Manometer stand with 4 tubes positioning. Tubes, ruler and anchoring system has to be ordered separatly.
Dimensions: 1152 x 250 x 34 mm
Ruler  38-T0183/R Ruler for T0183/MS
Manometer Tubes 38-T0183/6 */** Manometer tube 6 mm dia. Connecting valve can be ordere separatly (T0183/6C)
 38-T0183/8 */** Manometer tube 8 mm dia.  Connecting valve can be ordere separatly (T0183/8C)
38-T0183/14 */** Manometer tube 14 mm dia.  Connecting valve can be ordere separatly (T0183/14C)
38-T0183/22*  Manometer tube 22 mm dia.  Connecting valve can be ordere separatly (T0183/22C)
Anchoring system 38-T0183/A */** Anchoring system to fix manometer tubes with connecting valves on T0183/MS
Control Panel  38-T0183/P Control Panel used for saturating sample

Note 1 :
* Standard configuration for Falling Head apparatus included in T0185/KIT1
** Standard configuration for Falling Head apparatus on compacted included in T0185/KIT2  
 

Documents

Contact Us

Controls Group USA, Inc.

2521 Technology Drive, Suite 203
Elgin, Il 60124.
Phone: +1 844 291 4305
Email: info@controls-usa.com
www.controls-usa.com

Having read the information on the data processing:

È necessario effettuare una scelta per proseguire

We will never divulge your data to third parties.

By clicking send button, I confirm that I request the service indicated in point a) of these guidelines; my consent to the processing of data for the purposes of the service, including the processing methods mentioned in these guidelines, including possible processing carried out in EU member states or non-EU countries.